Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
800-819-0559 (Landline) | 400-619-0559 (Cell)
Home >> Temperature Products >> Thermocouples >> High Temperature The... >> XTA, XMO, XPA, XIN Series

Very High Temperature Exotic Thermocouple Probes

XTA, XMO, XPA, XIN Series   
 
XTA, XMO, XPA, XIN Series:Very High Temperature Exotic Thermocouple Probes
Click for larger image.
   
Sheaths
• Tantalum
• Molybdenum
• Platinum/Rhodium
• Inconel 600
Thermocouple Elements
• Tungsten/Rhenium
• Platinum/Rhodium
Insulations
• Hafnium Oxide (HfO2)
• Magnesia (MgO)
• Alumina (Al2O3)
Mating Connector Sold Separately!

View related products - Thermocouples

Click to scroll below to order See Specs PDF Related Items View a printer friendly page

OMEGA™ Exotic Thermocouple Probes are designed for use in extreme temperatures, up to 2315°C (4200°F). These probes utilize either Platinum/Rhodium (types R, S, or B) or Tungsten/Rhenium (types G, C, or D) elements, with a variety of insulations and sheath materials. Depending upon the sheath material selected, these probes may be used in inert, oxidizing, reducing or vacuum conditions. The maximum temperature is based on the lowest max. temperature of the element, insulation and sheath material. Five cold end probe terminations are available: replacement probe, subminiature or standard size ceramic connector, heavy-duty standard size, molybdenum-sheathed nylon connector, or transition joint with 72-inch lead wire.

Sheath Materials
CodeMaterialMax.
Operating
Temp.
Working
Environment
Approx.
Melting
Point
Remarks
XTATantalum2300°C
4200°F
Vacuum3000°C
5425°F
Resists Many Acids
and Weak Alkalies.
Very Sensitive to
Oxidation Above 570°F
XMO*Molybdenum2200°C
4000°F
Inert
Vacuum
Reducing
2610°C
4730°F
Sensitive to Oxidation
Above 400°F
Non-bendable
XPAPlatinum-
Rhodium
Alloy
1650°C
3000°F
Oxidizing
Inert
1870°C
3400°F
No Attack by SO2
at 2000°F. Silica Is
Detrimental. Halogens
Attack at High Temp.
XINInconel
600
1150°C
2100°F
Oxidizing
Inert
Vacuum
1400°C
2550°F
Excellent Resistance
to Oxidation at High
Temp. Hydrogen Tends
to Embrittle. Very
Sensitive to Sulfur
Corrosion
*Refractory metals are extremely sensitive to any trace of oxygen above approximately 260°C
(500°F). Must be used in vacuum or in very pure inert gases such as Hellium or Argon.


Insulation Materials
CodeMaterialMax.
Operating
Temp.**
Approx.
Melting
Point
Remarks
HHafnia
(HfO2)
2500°C
4530°F
2830°C
5125°F
Nontoxic substitute for BeO.
High Thermal Conductivity.
MMagnesia
(MgO)
1650°C
3000°F
2790°C
5050°F
Hygroscopic.
Compacts Well.
AAlumina
(Al2O3)
1540°C
2800°F
2010°C
3650°F
Requires Considerable
Volume Reduction to
Compact Satisfactorily.
Note:
For temperatures above 1000°C (1800°F), all insulating materials experience a
substantial decrease in resistivity with increasing temperatures.

** Values given are for compacted insulation. For uncompacted hard-fired insulators,
useful temperature range can be 5 to 110°C (100 to 200°F) higher.
Molybdenum sheathed probes are not recommended in applications where they will be
exposed to carbon, including graphite.

For Graphite environments, Consult Omega's Custom Engineering Department for Pricing and Delivery on Tungsten Coated Molybdenum sheathed T hermocouples.

Termination Style Q
Type OGP heavy-duty, color-coded male and female connectors. Add $10 to base price.
Termination Style TJ
Heavy-duty transition termination with 72-inch leads. Add $13 to base price.
Termination Style HX
Type NHX high temperature ceramic male and female connectors with color identification dot. Add $17 to base price.
Termination Style SX
Type SHX miniature high temperature ceramic male and female connectors with color identification dot. Add $11 to base price.
Termination Style RP
Replacement probe style with 1" bare wire leads. No additional price.

Calibration1 Atmosphere2
Max.Temp3
Model Number
C
W-5% Re
vs. W-26% Re
V.
2300°C
4200°F
XTA-W5R26-U-062-30-H-*-**
XTA-W5R26-U-125-30-H-*-**
XTA-W5R26-U-125-24-H-*-**
R*
Pt-13% Rh
vs. Pt
V.
1475°C
2700°F
XTA-P13R-U-062-30-M-*-**
XTA-P13R-U-125-24-M-*-**
XTA-P13R-U-062-30-H-*-**
XTA-P13R-U-125-24-H-*-**
C
W-5% Re
vs. W-26% Re
I.V.R.
2200°C
4000°F
XMO-W5R26-U-125-30-H-*-**
XMO-W5R26-U-250-30-H-*-**
C
W-5% Re
vs.W-26% Re
I.V.R.
1540°C
2800°F
XMO-W5R26-U-250-30-A-*-**
XMO-W5R26-U-062-40-A-*-**
XMO-W5R26-U-125-30-A-*-**
R*
Pt-13% Rh
vs. Pt
I.V.R.
1480°C
2700°F
XMO-P13R-U-125-30-A-*-**
XMO-P13R-U-250-24-A-*-**
C
W-5% Re
vs. W-26% Re
O.I.V.
1540°C
2800°F
XPA-W5R26-U-125-30-A-*-**
R*
Pt-13% Rh
vs. Pt
O.I.V.
1480°C
2700°F
XPA-P13R-U-062-30-M-*-**
XPA-P13R-U-125-24-M-*-**
XPA-P13R-U-125-30-A-*-**
C
W-5% Re
vs. W-26% Re
O.I.V.
1150°C
2100°F
XIN-W5R26-U-062-30-M-*-**
XIN-W5R26-U-125-30-M-*-**
R*
Pt-13% Rh
vs. Pt
O.I.V.
870°C
1600°F
XIN-P13R-U-062-30-M-*-**
XIN-P13R-U-125-30-M-*-**
XIN-P13R-U-125-24-M-*-**
XIN-P13R-U-187-24-M-*-**
XIN-P13R-U-250-24-M-*-**
XIN-P13R-U-250-20-M-*-**
* Specify Termination Style: Q, TJ, HX, SX, or RP
** Specify Probe Length in inches


  
Note 1:   Prices subject to change
Please consult the Sales
Department for current pricing.
Note 2:   Atmospheres:
  O-Oxidizing
   I-Inert
   V-Vacuum
   R-Reducing.
Note 3:   Maximum service temperatures shown are for probes with the largest available gage wire leads. Consult Engineering for ratings of other dimension probes.
Note 4:   Bending: XPA sheathed probes with platinum elements be bent in the field.
Note 5:   Some probes available in dual configurations. Check with Sales Department.
Order on www.omegaengineering.cn and 5% will be discounted when you checkout.
  To Order (Specify Model Number)
All list prices are pre-VAT rate not including tax and shipping
 
 Part Number   Availability   Price(RMB)   Description    Qty.
 Example part numbers are shown below. Use the box below to order specific models
 Tantalum Sheath
 XTA-W5R26-U-125-30-H-MQ-6 6 Weeks   ¥3,850.00    Thermocouple Type C, W-5% Re vs. W-26% Re, Tantalum Sheath, Ungrounded Junction, 0.125 inch sheath diameter, 30 AWG wire, Hafnium Oxide (HFO2) Insulation, HMPW Miniature Connector, 6 inch length  
 XTA-W5R26-U-250-24-H-Q-14 6 Weeks   ¥11,700.00    Thermocouple Type C, W-5% Re vs. W-26% Re, Tantalum Sheath, Ungrounded Junction, 0.250 inch sheath diameter, 24 AWG wire, Hafnium Oxide (HFO2) Insulation, HSTW Standard Connector, 14 inch length  
 XTA-W5R26-U-062-30-H-MQ-6    Consult sales   Thermocouple Type C, W-5% Re vs. W-26% Re, Tantalum Sheath, Ungrounded Junction, 0.062 inch sheath diameter, 30 AWG wire, Hafnium Oxide (HFO2) Insulation, HMPW Miniature Connector, 6 inch length  
 Molybdenum Sheath
 XMO-W5R26-U-187-24-A-Q-72 6 Weeks   ¥27,570.00    Thermocouple Type C, W-5% Re vs. W-26% Re, Molybdenum Sheath, Ungrounded Junction, 0.187 inch sheath diameter, 24 AWG wire, Alumina (Al2O3) Insulation, HSTW Standard Connector, 72 inch length  
 XMO-W5R26-U-062-40-A-Q-36 6 Weeks   ¥11,745.00    Thermocouple Type C, W-5% Re vs. W-26% Re, Molybdenum Sheath, Ungrounded Junction, 0.062 inch sheath diameter, 40 AWG wire, Alumina (Al2O3) Insulation, HSTW Standard Connector, 36 inch length  
 XMO-W3R25-U-125-30-H-Q-27.5 6 Weeks   ¥12,005.00    Thermocouple Type D, W-3% Re vs. W-25% Re, Molybdenum Sheath, Ungrounded Junction, 0.125 inch sheath diameter, 30 AWG wire, Hafnium Oxide (HFO2) Insulation, HSTW Standard Connector, 27.5 inch length  
 Platinum-Rhodium Alloy Sheath
 XPA-P30R-U-062-30-M-RP-6.150    Consult sales   Thermocouple Type B, Pt-30% Rh vs. Pt, Platinum-Rhodium Alloy Sheath, Ungrounded Junction, 0.062 inch sheath diameter, 30 AWG wire, Magnesia (MgO) Insulation, Replacement Probe, 6.150 inch length  
 XPA-W5R26-U-125-30-A-HX-6    Consult sales   Thermocouple Type C, W-5% Re vs. W-26% Re, Platinum-Rhodium Alloy Sheath, Ungrounded Junction, 0.125 inch sheath diameter, 30 AWG wire, Alumina (Al2O3) Insulation, NHX High Temperature Ceramic Connector, 6 inch length  
 XPA-P13R-U-062-30-M-TJ-6 6 Weeks   ¥28,865.00    Thermocouple Type R, Pt-13% Rh vs. Pt, Platinum-Rhodium Alloy Sheath, Ungrounded Junction, 0.062 inch sheath diameter, 30 AWG wire, Magnesia (MgO) Insulation, Heavy-Duty Transition Termination, 6 inch length  
 Inconel 600 Sheath
 XIN-P13R-U-125-30-A-TJ-24-DUAL    Consult sales   Thermocouple Type R, Pt-13% Rh vs. Pt, Inconel 600 Sheath, Ungrounded Junction, 0.125 inch sheath diameter, 30 AWG wire, Alumina (Al2O3) Insulation, Heavy-Duty Transition Termination, 24 inch length, Dual Element  
 XIN-P13R-U-062-30-M-SX-26    Consult sales   Thermocouple Type R, Pt-13% Rh vs. Pt, Inconel 600 Sheath, Ungrounded Junction, 0.062 inch sheath diameter, 30 AWG wire, Magnesia (MgO) Insulation, SHX Miniature High Temperature Ceramic Connector, 26 inch length  
 XIN-P10R-U-062-30-M-TJ-6    Consult sales   Thermocouple Type S, Pt-10% Rh vs. Pt, Inconel 600 Sheath, Ungrounded Junction, 0.062 inch sheath diameter, 30 AWG wire, Magnesia (MgO) Insulation, Heavy-Duty Transition Termination, 6 inch length  
 Sold Separately, Mating Connector & clamp & other accessory Part Number
 HSTW-C-F 6 Weeks   ¥198.00    Termination Style Q Mating Connector  
 HSTW-R-F    Consult sales   Termination Style Q Mating Connector  
 NHX-C-F In Stock   ¥159.00    Termination Style HX Mating Connector  
 NHX-R-F    Consult sales   Termination Style HX Mating Connector  
 HMPW-C-F In Stock   ¥104.00    Termination Style MQ Mating Connector  
 HMPW-R-F    Consult sales   Termination Style MQ Mating Connector  
 SHX-C-F In Stock   ¥111.00    Termination Style SX Mating Connector  
 SHX-R-F    Consult sales   Termination Style SX Mating Connector  
 PCLM-SMP In Stock   ¥14.50    Cable Clamp for HMPW  
 PCLM In Stock   ¥14.50    Cable clamp for HSTW  
 PCLM-NHX 2 Weeks   ¥27.50    cable clamp for NHX  
 PCLM-SHX In Stock   ¥14.50    Cable clamp for SHX  
 SMCL 2 Weeks   ¥15.50    Safety clip, HMPW  
 SFCL In Stock   ¥30.00    Safety clip for HSTW  
 HTCL 6 Weeks   ¥27.50    Safety clip for NHX  
Price are shown in RMB.

 Note:
Note 1: Prices subject to change. Please consult the Sales Department for accurate pricing.
Note 2: Atmospheres:
      O-Oxidizing
      I-Inert
      V-Vacuum
      R-Reducing
Note 3: Maximum service temperatures shown are for probes with the largest available gage wire leads. Consult Engineering for ratings of other dimension probes.
Note 4: Bending: XPA sheathed probes with platinum elements can be bent in the field.
Note 5: Some probes available in dual configurations. Check with Sales Department.

 Related Links - Related Products
 Related Products
EXXC-C, EXXT-C, EXXL-C and EXGG-C EXXC-C, EXXT-C, EXXL-C and EXGG-C:
C Type Thermocouple Extension Wire
   
Keywords:Tungsten Coated Thermocouples . Very High Temperature Exotic Thermocouple Probes, Tantalum, Molybdenum, Platinum/Rhodium, Inconel 600 Sheaths, Tungsten/Rhenium and Platinum/Rhodium Thermocouple Elements, Berylia, Magnesia, Alumina I, ac motor controls control relay

   Back to top Back to top