 Programmable Chart Recorders 100mm and 180 mm - Discontinued |  | RD200 and RD2800 Series |  |  
  |  |  
| 
	|  |  |   
    |  |  | 
    
    	|  |  |     
		       
		     
		        |  | Simultaneous Digital Displays of Multipoint Data 
 |  
		        |  | Universal input The recorders accept total 56 ranges of 10 DC voltage ranges, 35 thermocouple ranges and 11 resistance thermometer ranges, and these ranges can be programmed for each channel. 
 |  
		        |  | Universal power voltage 100VAC to 240VAC, 50/60Hz 
 |  
		        |  | Clear trend and digital printings Cassette type wire-dotting system 6-color ink ribbon for clear trend and digital printings 
 |  
		        |  | Alarm Display/Printings 
 |  
		        |  | Chart illumination Convenient to confirm printed data in night or dark places 
 |  
		        |  | Software Package “KIDS” Available 
 |  
		        |  | Conforms to CE, UL, and CSA Standards 
 |  
		  	|  |  |  |  |  
	
	
|  |  
	| 
	
		|  | 
    	
      	| The RD200 and RD2800 series have been discontinued. Please see the CTXL Series as a possible alternative or contact our sales department.  Accessories are still available.
 
 The RD200 and RD2800 Series
chart recorders are 100 mm,
multipoint, hybrid recorders that can
print/display multichannel and alarm
data simultaneously. A total of
56 ranges can be programmed for
each channel: 35 thermocouple,
11 RTD, and 10 DC voltage. The
user can also program up to 4 levels
of alarm for each channel; optional
alarm outputs are available. The
recorders display alarm settings
(status and channels), and can print
channel alarms and alarm numbers.
A data acquisition software
package, “KIDS”, lets the user
create real-time and historical
data/trend displays. The RD200 and
2800 Series chart recorders are
manufactured in ISO9001-certified
facilities and conform to CE, UL,
and CSA safety standards.
 
 Data acquisition software package "KIDS" (RD2800-KIDS)
 The "KIDS" is a software package for storing data being measured by 
RD200 and RD2800 series recorders and for replaying of
the stored data.
 Main function and features:
 - Data processing: Up to 5 sets (max. 100 channels)
- Real-time data, real-time trend, historical data, historical trend and 
daily report
 - Communications interfaces: RS-232C, RS-422A or RS-485
- Stored data: Enable to export to Microsoft Excel, Lotus 1-2-3 and other application software
 - OS: Windows 95/98, Windows NT4.0
 
 Engineering software package "PASS" (RD2800-PASS)
 The "PASS" is a software package, through a communications 
interface (optional) or a configuration port, for programming
parameters of RD200 and RD2800 series recorders by a personal 
computer.
 Main functions and features:
 - Input parameters: Ranges, scales, tags, engineering units, alarms, burnout
 - Printing parameters: Chart speed, data interval, subtract printing, zone printing,  automatic range-shift printing
- Operation: Message printing
 - Others: Clock setting, temperature units (ºC, ºF), alarm deadband, communications specification (for programming through a
configuration port only)
 - OS: Windows95/98, WindowsNT4.0
 
 |  |  |  |  |  |  |  | | † Price are shown in RMB. 
 Note: Optional boards are NOT field installable for the RD200 models
 Other options available:
 -MATH (mathematical calculation) $154
 -TOT (totalizer) $154
 -FLOW (totalizing/flow correction computation function for pen-type recorder only) $291
 -TFLOW (basic + totalizing/flow correction computation function for pen-type recorder only) $ 146. Only one option can be ordered with each unit.
 (OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
 
 | 
 |  
	|  | 
	
		|  |  |  
		|  |  |  |  
		|  | Part Number Builder |  |  
		|  |  |  |  
		|  | 
		  
		    |  |   
		    | Option Descriptions |   
		    | (1) | Input |   
		    |  | Select 201 for 1 input (Paper size 100 mm 1-pen)
 202 for 2 input (Paper size 100 mm 2-pen)
 203 for 3 input (Paper size 100 mm 3-pen)
 204 for 4 input (Paper size 100 mm 4-pen)
 206 for 6 input (Paper size 100 mm 6-dot points)
 2801 for 1 input (Paper size 180 mm 1-pen)
 2802 for 2 input (Paper size 180 mm 2-pen)
 2803 for 3 input (Paper size 180 mm 3-pen)
 2804 for 4 input (Paper size 180 mm 4-pen)
 2806 for 6 input (Paper size 180 mm 6-dot points)
 2812 for 12 input (Paper size 180 mm 12-dots points)
 2824 for 24 input (Paper size 180 mm 24-dots points)
  
		    | (2) | Field Installable Option |   
		    |  | Select Nothing(leave field blank) for None
 -C422 for RS422A communication interface (RD2800 Models only)
 -C485 for RS485 communication interface (RD 2800 Models only)
 -C232 for RS232C communication interface (RD 2800 Models only)
 -EI for Ethernet interface (RD 2800 Models only)
 -R6 for 6-point mechanical relay C SPST and remote contacts (RD 2800 Models only)
 -R12 for 12-point mechanical relay C SPST and remote contacts (RD 2800 Models only)
 -R24 for 24-point mechanical relay C SPST and remote contacts (RD 2800 Models only)
  
		    | (3) | Additional Options (Not Field Installable) |   
		    |  | Select Nothing(leave field blank) for None
 -MATH for Mathematical calculation
 -TOT for Totalizer
 -FLOW for Totalizing/flow correction computation function (pen-type only)
 -TFLOW for Basic + totalizing/flow correction computation function (pen-type only)
 |  
		      | NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |  |  |  |  |  
		|  |  
 |  |  | 
 |  |  | 
	
	