 Discontinued -  Diffused Semiconductor Pressure TransducerRugged Aerospace Design
 |  | PX6000-MV |  |  
  |  |  
| 
	|  |  |   
    | 
        
			| Diffused Semiconductor Pressure Transducer 
  |          
           | Click for larger image. |  |  |  |  |  
	
	
|  |  
	| 
	
		|  | 
    	
      	| OMEGA’s PX6000 Series pressure
transducers fit easily into your
application. These low-cost
transducers are small and light,
and mounting requires no bulky
structures. You select from
3 electrical terminations and
6 pressure fittings. The sensor is a
small [about 2.54 cm (0.1")] square
silicon chip with 4 diffused strain
gages, mounted in the stainless
steel case. Laser-trimmed resistors
provide temperature compensation
and adjust zero balance and span.
The 30 mV full range output is
compatible with most amplifiers
and data acquisition systems.
 
 The PX6000 uses solid state media
isolation for improved reliability.
Thin films of chemically inert
materials are deposited or grown on
the chip surface to provide electrical
isolation between the sensor and
pressure medium. The sensor is
less sensitive to vibration and
more dependable in high-shock
environments. Corrosion resistance
is outstanding, and the isolation will
remain effective because there is
no gel or oil column to deteriorate.
 
 
 The PX6000 is also available in metric configurations, with G1/4 or G1/8 ports, and 
models from 0-1 to 0-25 bar pressure ranges.
Please see the PXM6000 for complete details, or contact our Pressure department for more information..
 
 SPECIFICATIONS
 ELECTRICAL
 Excitation: 10 Vdc
 Output: 3 mV/V ± 10%
 Input Resistance: 2000 Ω minimum
 Output Resistance: 1000 Ω minimum, 1500 Ω maximum
 Zero Balance: 0 mV ±5% FSO
 Dielectric Isolation Resistance: 100 MΩ minimum at 50 Vdc applied between the case or a conductive medium and the bridge circuit
 Sensing Element: 4-active-arm bridge using a micro-machined diffused silicon diaphragm sensor, thin-film media and dielectric isolation barriers
 Temperature Sensor: Output resistance @ 24°C (75°F) 900 to 1500 Ω
 Temperature Coefficient: 8% min, 10% max per 55.5°C (100°F)
 
 PERFORMANCE
 Accuracy: Combined linearity, hysteresis and repeatability ≤±0.25% FS for all ranges
 
 ENVIRONMENTAL
 Operating Temp Range: -54 to 150°C (-65 to 300°F)
 Compensated Temp Range: -54 to 121°C (-65 to 250°F)
 Thermal Effects:
 Span: ≤±0.02% of FS/°F
 Zero: ≤±0.02% of FS/°F
 Vibration Sensitivity: At 35g peak sinusoidal vibration from 10 Hz to 2000 Hz (½" D.A.), the output shall not exceed 0.04% FS/g for 15 psi range to 0.005% FS/g for 100 psi and above
 Natural Frequency: Greater than 35 kHz for 100 psi and above
 Shock: 100 g, 11 ms half sine wave without damage
 
 PRESSURE
 Proof Pressure: 2 times rated pressure will not cause changes in performance beyond the specified tolerances
 Burst Pressure: 3 times rated pressure for pressure ranges below 200 psi, or 2.5 times rated pressure for pressure ranges above 200 psi will not cause rupture of the pressure sensor
 
 MECHANICAL
 Wetted Parts: 316 stainless steel, silicon nitride, Pyrex® glass, epoxy, Kovar®
 Electrical Connection:
 Standard: PTIH-10-6P
 Optional: 0.6 m (2') cable or 4-pin solder terminal header
 Pressure Port:
 Standard: MS33656-4 male
 Optional: MS33649-4 female, 1/4-18 or 1/8-27 NPT male or female
 Weight: 4 oz max, excluding pressure fitting and electrical connection
 Mating Connector: PTS06A-10-6S (not included)
 |  |  |  |  |  |  |  | | † Price are shown in RMB. 
 Note: Metric Ranges Available - Consult Engineering
 
 | 
 |  
	|  | 
	
		|  |  |  
		|  |  |  |  
		|  | Part Number Builder |  |  
		|  |  |  |  
		|  | 
		  
		    |  |   
		    | Option Descriptions |   
		    | (1) | Pressure Port |   
		    |  | Select L for MS33656-4 Male
 M for MS33649-4 Female
 A for 1/8-27 NPT Male
 B for 1/8-27 NPT Female
 C for 1/4-18 NPT Male
 D for 1/4-18 NPT Female
  
		    | (2) | Electrical Connection |   
		    |  | Select 1 for PT1H-10-6P Connector or equal (mating connector not included)
 0 for 2' (6m) cable (std) +2$/ft over 2'
 3 for 4-pin Eyelet Header (no charge)
  
		    | (3) | Range |   
		    |  | Select 30 for 30 to 0 in-Hg (Vacuum only)
 015 for 0-15 psi
 020 for 0-20 psi
 050 for 0-50 psi
 100 for 0-100 psi
 200 for 0-200 psi
 300 for 0-300 psi
  
		    | (4) | Units |   
		    |  | Select VAC for Vacuum Model
 G for Gage Model
 A for Absolute Model
  
		    | (5) | Output |   
		    |  | Select V for mV/V Output
 5T for 0 to 5 Vdc Output
 I for 4 to 20mA Output
  
		    | (6) | Options |   
		    |  | Select for No Options
 -CAL11 for 11 point NIST Calibration $250 adder
 -xxFT for Extra length of cable $2/ft over 3ft
 |  
		      | NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |  |  |  |  |  |  |  |  
		|  |  
 |  |  | 
 |  |  | 
	
	
		| Related Links - 
		  Related Products |  |  
		|  |  
		| 
		     
		      | 
		          
		          
		           
		          
		          
		          
		          
		          
		          
		          
		          
		          
		          
		          
		          
		          
		          
		          
		            | Related Products |  
		            |  |  
		            | 
		                
		                  
		                  |  | DP41: |  
		                    
		                    | 1/8 DIN High Performance Temperature, Process and Strain Meter |  
		                  |  |  
		                  |  |  |  |  |  
		|  |  |  |