Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
800-819-0559 (Landline) | 400-619-0559 (Cell)
Home >> Flow and Level Produ... >> Turbine, Paddle Whee... >> Turbine Flow Meters >> FTB-100 Series

Turbine Flowmeters with Economical Ball Bearing Design

FTB-100 Series   
1 year warranty
 
Turbine Flowmeters with Economical Ball Bearing Design
FTB-100 Series:Turbine Flowmeters with Economical Ball Bearing Design
Click for larger image.
   
NIST Certificate Included for Water
±1/2% Rdg Accuracy
Non-Metallic Bearing Retainers for Long Life
Replacement Bearings Field Installable Without Loss of Calibration
Disassembles Quickly for Easy Maintenance
Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
4 to 20 mA, 0-5 V, and Scaled Frequency Outputs Available

View related products - Turbine, Paddle Wheel & Positive Displacement Flow Meters

Click to scroll below to order See Specs PDF Manuals Related Items View a printer friendly page

The FTB-100 Series of turbine meters have a sealed ball bearing design for high accuracy performance (±½% of reading, not full scale) at an economical cost. The non-metallic bearing retainers minimize friction, thereby allowing these meters to be used with clean fluids that have poor lubricating properties ( i.e.water). Ball bearings also give the widest linear flow range, particularly in larger turbines. Bearing replacement and clean-up are fast and easy, since all internal parts are easily accessible by removing a single nut.

These turbine flowmeters have a low mass rotor design which allows rapid dynamic response, so they can be used in pulsating flow applications. Deflector cones eliminate downstream thrust on the rotor and allow hydrodynamic positioning of the rotor between the cones. This provides wider rangeability and longer bearing life than conventional turbine flowmeters. Integral flow-straightening tubes minimize the effects of upstream turbulence.
FTB-100 Turbine Meters are available with integral signal conditioners (as shown in photo) which provide scaled and unscaled frequencies, 4-20 mA, or 0-5 Volt outputs. Units without integral signal conditioners are supplied with mating connector for two-wire hook-up.

SPECIFICATIONS
Accuracy: ±½% of reading
Repeatability: ±0.1% of reading
Maximum Temperature Range: -268 to 232°C (-450 to 450°F)
Maximum Intermittent Overrange: 150% of maximum range
Minimum Output Amplitude: 30 mV Peak-to-Peak Unscaled Pulse
Materials of Construction:
   Body: 304 stainless steel; 1/2 NPT bodies contain Silver Solder. 3/4 NPT and larger are welded.
   Rotor: 17-4 pH steel
   Bearings: Ceramic
Minimum straight pipe requirements: 10 pipe diameters upstream, 5 downstream

Model No. Fittings Linear Flow Range
Water
Max Operating Pressure Max Pressure Drop Length
mm (in)
Nominal
K-Factor
Pulses/Gal
Weight
kg (lb)
LPM GPM
FTB-101 ½ MNPT 1.32 to 13.2 0.35 to 3.5 5000 psig 3.0 psid 62 (2.45) 13,000 0.4 (1)
FTB-102 ½ MNPT 2.84 to 28.4 0.75 to 7.5 5000 psig 5.0 psid 62 (2.45) 10,000 0.4 (1)
FTB-103 ½ MNPT 4.73 to 36 1.25 to 9.5 5000 psig 5.2 psid 62 (2.45) 6,000 0.4 (1)
FTB-104 ¾ MNPT 6.62 to 61 1.75 to 16 5000 psig 3.0 psid 70 (2.75) 4,100 0.4 (1)
FTB-105 ¾ MNPT 9.5 to 110 2.5 to 29 4250 psig 5.0 psid 83 (3.25) 2,200 0.4 (1)
FTB-106 1 MNPT 15 to 227 4 to 60 3850 psig 5.1 psid 89 (3.5) 640 0.9 (2)
FTB-107 1¼ MNPT 23 to 352 6 to 93 3850 psig 4.3 psid 99 (3.88) 410 0.9 (2)
FTB-108 1½ MNPT 30 to 492 8 to 130 3000 psig 3.0 psid 111 (4.38) 230 1.4 (3)
FTB-109 2 MNPT 57 to 852 15 to 225 2500 psig 3.3 psid 121 (4.75) 120 1.8 (4)
FTB-110 2½ MNPT 95 to 1514 25 to 400 2250 psig 4.0 psid 154 (6.06) 62 2.3 (5)
FTB-111 3 MNPT 151 to 2460 40 to 650 2000 psig 4.0 psid 191 (7.50) 55 3.2 (7)
Order on www.omegaengineering.cn and 5% will be discounted when you checkout.
  To Order (Specify Model Number)
All list prices are pre-VAT rate not including tax and shipping
 
 Part Number   Availability   Price(RMB)   Description    Qty.
 FTB-101 7 Weeks   ¥14,225.00    0.35-3.5 GPM Range, Water; 1/2 MNPT  
 FTB-102 5 Weeks   ¥14,225.00    0.75-7.5 GPM Range, Water; 1/2 MNPT  
 FTB-103 9 Weeks   ¥14,225.00    1.25-9.5 GPM Range, Water; 1/2 MNPT  
 FTB-104 9 Weeks   ¥14,225.00    1.75-16 GPM Range, Water; 3/4 MNPT  
 FTB-105 9 Weeks   ¥14,225.00    2.5-29 GPM Range, Water; 3/4 MNPT  
 FTB-106 2 Weeks   ¥15,740.00    4-60 GPM Range, Water; 1 MNPT  
 FTB-107 5 Weeks   ¥17,090.00    6-93 GPM Range, Water; 1¼ MNPT  
 FTB-108    Consult sales   8-130 GPM Range, Water; 1½ MNPT  
 FTB-109 5 Weeks   ¥20,275.00    15-225 GPM Range, Water; 2 MNPT  
 FTB-110 9 Weeks   ¥26,190.00    25-400 GPM Range, Water; 2½ MNPT  
 FTB-111 9 Weeks   ¥26,190.00    40-650 GPM Range, Water; 3 MNPT  
Price are shown in RMB.

 Note: Comes with NIST certificate for water and complete operator’s manual.
Standard NIST calibration: Viscosity = 1CK: no charge; 0.8 CK to 0.99 CK: add $370; 2 CK to 100 CK: for FTB-101 through FTB-107, add $625; for FTB-108 and FTB-109, add $625, and for FTB-110 and FTB-111, add $465.
If an integral signal conditioner is required please order as a system. Omega will scale the signal conditioner to the turbine meter.
Example: SYS/FTB-101/FLSC-C1-LIQ, scaled system includes: Signal Conditioner, Enclosure, Turbine Meter and Fitting, $1954.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
 Ordering Example: (1) FTB-105 Liquid turbine meter calibrated to water 2.5 to 29 GPM, .75, ¥14,225.00

 Related Links - Related Products
 Related Products
DPF700 Series DPF700 Series:
1/8 DIN 6-Digit Rate Meter/Totalizer - Discontinued
DPF70 Series DPF70 Series:
Frequency Input Ratemeter/Totalizer
FTB890 Series FTB890 Series:
 - Discontinued
FLSC-C1-LIQ Series FLSC-C1-LIQ Series:
integral or remote signal conditioner
FLSC-C3-LIQ Series FLSC-C3-LIQ Series:
integral or remote signal conditioner
CL535 CL535:
Frequency Calibrator with Totalizer
   
Keywords:Turbine Flowmeters with Economical Ball Bearing Design, liquid flow sensor , calibrating a ph meter digital clamp meter dmm probe multimeter frequency

   Back to top Back to top