 K Type Thermocouple Extension Wire |  | EXGG-K, EXTT-K, EXPP-K and EXFF-K |  |  
  |  |  
|  |  
	
	
|  |  
	| 
	
		|  | 
    	
      	| ANSI Color Code: Positive Wire, Yellow ; Negative Wire, Red; Overall, Yellow
 
 
 
 
 
 
 
 The "To Order"  box contains some examples of popular models. Use the "Part Number Builder" (Below Table) to get pricing for all available models. Use the table below as a guide for types available
 
	
		| 
				
					| Insulation | AWG No.
 | Model Number
 | Type Wire
 | Insulation | Max. Temp* | Nominal Size
 | Wt. lb/1000'
 |  
					| Conductor | Overall | °F | °C |  
					| Glass Neoflon
 PFA
 | 16 | EXGG-K-16 | Solid | Glass Braid | Glass Braid | 392 | 200 | .085 x .130 | 23 |  
					| 16 | EXTT-K-16 | Solid | PFA | PFA | 392 | 200 | .086 x .152 | 21 |  
					| 20 | EXTT-K-20 | Solid | PFA | PFA | 392 | 200 | .068 x .116 | 11 |  
					| 24 | EXTT-K-24 | Solid | PFA | PFA | 392 | 200 | .056 x .092 | 7 |  
					| Polyvinyl | 14 | EXPP-K-14 | Solid | Polyvinyl | Polyvinyl | 221 | 105 | .134 x .288 | 36 |  
					| 16 | EXPP-K-16 | Solid | Polyvinyl | Polyvinyl | 221 | 105 | .123 x .207 | 26 |  
					| 16 | EXPP-K-16S | 7 x 24 | Polyvinyl | Polyvinyl | 221 | 105 | .139 x .226 | 26 |  
					| 18 | EXPP-K-18S | 7 x 26 | Polyvinyl | Polyvinyl | 221 | 105 | .138 x .205 | 22 |  
					| 20 | EXPP-K-20 | Solid | Polyvinyl | Polyvinyl | 221 | 105 | .095 x .151 | 16 |  
					| 20 | EXPP-K-20S | 7 x 28 | Polyvinyl | Polyvinyl | 221 | 105 | .123 x .175 | 16 |  
					| 24 | EXPP-K-24 | Solid | Polyvinyl | Polyvinyl | 221 | 105 | .075x .120 | 5 |  
					| 24 | EXPP-K-24S | 7 x 32 | Polyvinyl | Polyvinyl | 221 | 105 | .082 x .134 | 11 |  
					| Neoflon FEP
 | 16 | EXFF-K-16 | Solid | FEP | FEP | 392 | 200 | .086 x .152 | 21 |  
					| 20 | EXFF-K-20 | Solid | FEP | FEP | 392 | 200 | .068 x .116 | 11 |  
					| 24 | EXFF-K-24 | Solid | FEP | FEP | 392 | 200 | .056 x .092 | 7 |  |  *Maximum temperature is for extension grade  wire or insulation, whichever is lower.Weight of spool and wire, rounded up to next highest lb. (does not include packing material).
 |  |  |  |  |  |  |  | | † Price are shown in RMB. 
 Ordering Example: (1) EXPP-K-24S-25 25 foot spool of extension grade thermocouple wire, type K, 24 gage, stranded, Polyvinyl over Polyvinyl insulation, ¥505.00
 | 
 |  
	|  | 
	
		|  |  |  
		|  |  |  |  
		|  | Part Number Builder |  |  
		|  |  |  |  
		|  | 
		  
		    |  |   
		    | Option Descriptions |   
		    | (1) | Insulation |   
		    |  | Select GG for Glass
 TT for Neoflon PFA
 PP for Polyvinyl
 FF for Neoflon FEP
  
		    | (2) | Wire Gauge |   
		    |  | Select 16 for 16 AWG (Avail GG TT PP FF)
 20 for 20 AWG (Avail TT PP FF)
 24 for 24 AWG ((Avail TT PP FF)
 14 for 14 AWG (PP Only)
 16S for 16 AWG Stranded (PP Only)
 18S for 18 AWG Stranded (PP Only)
 20S for 20 AWG Stranded (PP Only)
 24S for 24 AWG Stranded (PP Only)
  
		    | (3) | Special Limits of Error |   
		    |  | Select Nothing(leave field blank) for Standard
 -SLE for Special Limit of Error
  
		    | (4) | Spool Length in Feet |   
		    |  | Select 25 for 25 Ft
 50 for 50 Ft
 100 for 100 Ft
 200 for 200 Ft
 500 for 500 Ft
 1000 for 1000 Ft
 |  
		      | NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |  |  |  |  |  |  
		|  |  
 |  |  | 
 |  |  |  |  
	| Back to top
  
 
 |  |  |