 1/8 DIN Dual Input Process Panel Meter |  | DP6060 Series |  |  
  |  |  
| 
	|  |  |   
    | 
        
			| 1/8 DIN Dual Input Process Panel Meter 
  |          
           | Click for larger image. |  |  | 
    
    	|  |  |     
		       
		     
		        |  | Modular USB, RS232, RS485 Serial Communication Options and Relays 
 |  
		        |  | Math Functions: Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio, Concentration, and More 
 |  
		        |  | 0 to 20 mA, 4 to 20 mA, 0 to 5V, 1 to 5V, and ±10V Inputs 
 |  
		        |  | Large Dual-Line 6-Digit Display, 15 and 12 mm (0.60 and 0.46") 
 |  
		        |  | Sunlight Readable Display Models 
 |  
		        |  | NEMA 4X (IP65) Front 
 |  
		        |  | Universal 85 to 265 Vac, or 12/24 Vdc Input Power Models 
 |  
		        |  | Isolated 24 Vdc @ 200 mA Transmitter Power Supply 
 |  
		        |  | Free Software for Operation, Monitoring, and Programming 
 |  
		  	| View related products - Temperature & Process Meters, Industrial Timers and Counters
 
 
 |  |  |  |  
	
	
|  |  
	| 
	
		|  | 
    	
      	| The DP6060 Series process meter
combines two independently
programmed analog inputs
with powerful math functions
to make an advanced meter
capable of handling complex
math requirements common in
the process industry. Various
math functions may be applied
to the inputs including addition,
difference, average, multiplication,
division, ratio, and more. A
customizable dual-line display
allows a wide variety of input
variables, math calculations, or
units and tags to be displayed
based on your application needs.
Sunlight readable display models
have an extraordinarily bright LED
display. The DP6060 has two red
LED displays, an upper display
15 mm (0.60") high, and a lower
display 12 mm (0.46") high. Each
display is a full 6 digits (-99999 to
999999). The displays can be set
up to read input channels (A or B),
math function channel C, toggle
between A & B, B & C, A & C, A &
B & C, toggle between channels
A, B, or C & units, the max/min
of any of the channels, including
the math channel (C), set points,
gross (without tare) or net (with
tare) and gross values of channel
A or B, or the Modbus input. No
jumpers to set for input selection.
All setup and programming are
done via the front panel. Three
levels of password protection
help maintain the reliability of the
programming. The Copy feature
is used to copy (or clone) all the
settings from one DP6060 to
other meters in about 20 seconds!
The Copy function is a standard
feature on all meters. It does not
require a communications adaptor,
only an optional cable assembly.
The DP6060 minimizes the menu
selections by auto-detecting the
installed options to determine
what menu navigation is required.
 
 General Specifications
 Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
 Upper Display: 15 mm (0.60") high
 Lower Display: 12 mm (0.46") high
 Display Intensity: 8 intensity levels
 Display Update Rate: 5/second (200 ms)
 Overrange: Display flashes 999999
 Underrange: Display flashes -99999
 Display Assignment: The upper and lower displays may be assigned to process values for Channels A (Ch-A), B (Ch-B), or C (Ch-C), toggle between (Ch-A & Ch-B, Ch-A & Ch-C, Ch-B & Ch-C, and Ch-A, Ch-B, & Ch-C), toggle between Channel and units, show channel gross value (no tare) or toggle net (tare) and gross values, show relay set points, max and min values, or Modbus input; the second display may also be set to show engineering units or be off, with no display
 Front Panel: NEMA 4X (IP65)
 Programming Methods: 4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function
 Noise Filter: Programmable from 2 to 199 (0 will disable filter)
 Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
 Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
 Max/Min Display: Max (peak)/min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
 Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital inputs
 Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
 Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W maximum, or jumper selectable 12/24 Vdc ±10%, 15 W maximum
 Fuse (External, Required): UL recognized, 5 A maximum, slow blow; up to 6 meters may share one 5 A fuse
 Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA maximum (standard), (12/24 Vdc powered models rated @ 100 mA maximum); 5 or 10 Vdc @ 50 mA maximum, selectable with internal jumper J4
 Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
 Isolation: 4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
 Overvoltage Category: Installation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III
 Operating Temperature Range: -40 to 65°C
 Storage Temperature Range: -40 to 85°C
 Relative Humidity: 0 to 90% non-condensing
 Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters
 Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
 Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
 Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
 Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
 Weight: 269 g (9.5 oz)
 |  |  |  |  |  |  |  | | † Price are shown in RMB. 
 Note: Comes complete with 2 side mounting brackets and operator’s manual.
 
 | 
 |  
	|  | 
	
		|  |  |  
		|  |  |  |  
		|  | Part Number Builder |  |  
		|  |  |  |  
		|  | 
		  
		    |  |   
		    | Option Descriptions |   
		    | (1) | Output |   
		    |  | Select 6R0 for Dual input process panel meter
 6R2 for Dual input process panel meter with 2 relays
 6R4 for Dual input process panel meter with 4 relays
 6R5 for Dual input process panel meter with 4 to 20 mA output
 6R7 for Dual input process panel meter with 2 relays and 4 to 20 mA output
 7R0 for Dual input process panel meter
 7R2 for Dual input process panel meter with 2 relays
 7R3 for Dual input process panel meter with 4 to 20 mA
 6H0 for Dual input process panel meter
 6H2 for Dual input process panel meter with 2 relays
 6H3 for Dual input process panel meter with 4 to 20 mA output
 7H0 for Dual input process panel meter
 7H2 for Dual input process panel meter with 2 relays
 7H3 for Dual input process panel meter with 4 to 20 mA output
 |  
		      | NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |  |  |  
		|  |  
 |  |  | 
 |  |  |  |  
	| 
  	
    	| Keywords:1/8 DIN Dual Input Process Panel Meter 
 |  Back to top
  
 
 |  |  |