 Temperature/Process Controllers with Fuzzy Logic |  | CN72000 Series |  |  
  |  |  
| 
	|  |  |   
    | 
        
			| Temperature and Process Controllers with Fuzzy Logic 
  |          
           | Click for larger image. |  |  |  |  |  
	
	
|  |  
	| 
	
		|  | 
    	
      	| The CN72000 Series temperature/
process controllers set a new
quality, versatility, ease-of-use and
value standards. Including many
high-level standard features,
additional function setup items
appear in the control menu when a
function is selected, simplifying the
selection process. Units feature a
universal input for thermocouple
Types J, K, E, T, L, N, B, C, S and
R, RTD’s, differential input
(-10 to 10 mVdc); and process input
(0 to 20 mAdc, 0 to 10 Vdc). A
standard 24 V isolated, regulated
power supply is included; operates
most standard 4 to 20 mA
transmitters. Standard features
include autoune, fuzzy logic, fully
adjustable PID, auto/manual control
with smooth transfer and front panel
activation key, percent output
indicator, peak and valley indicator,
loop break protection and indication.
For process inputs, the display is
fully programmable from -1999 to
9999 with selectable decimal point
location. Most thermocouple and RTD inputs show whole or tenth
degree displays. The CN72000
Series can be programmed for
on/off, PID, heat/cool, or latching
alarm. All outputs are isolated from
the inputs. Outputs include 10 A
relay, and scalable 0 to 20 mAdc.
 
 
 
	SPECIFICATIONS| Input Types | Range | 
|---|
 | K Thermocouple | -129 to 1371°C (-200 to 2500°F) |  | J Thermocouple | -73 to 871°C (-100 to 1600°F) |  | T Thermocouple | -212 to 398°C (-350 to 750°F) |  | E Thermocouple | -73 to 982°C (-100 to 1800°F) |  | N Thermocouple | -73 to 1300°C (-100 to 2372°F) |  | R Thermocouple | -17 to 1760°C (0 to 3200°F) |  | S Thermocouple | -17 to 1760°C (0 to 3200°F) |  | B Thermocouple | 24 to 1820°C (75 to 3308°F) |  | L (J DIN) Thermocouple | -73 to 871°C (-100 to 1600°F) |  | C Thermocouple | -17 to 2320°C (0 to 4208°F) |  | Pt100 RTD (0.00385) | -200 to 875°C (-328 to 1607°F) |  | Pt100 RTD (0.00392) | -200 to 875°C (-328 to 1607°F) |  | RTD, 120 Ω Nickel (0.00628) | -80 to 320°C (-112 to 608°F) |  | RTD, Pt1000 (0.00385) | -200 to 875°C (-328 to 1607°F) |  | 0 to 20 mA*, 4 to 20 mA* | -1999 to 9999 |  | 0 to 10Vdc*, -10 to 10 Vdc*, -10 to 10 mVdc*
 | -1999 to 9999 |  Selectable Inputs: Thermocouple, RTD, DC voltage or DC current
 Input Impedance:
 Thermocouple: 3 MΩ minimum
 Voltage: 5000 Ω
 Current: 10 Ω
 RTD Current: 200 µA maximum
 Display: Two 4-digit, 7-segment, 6.35 mm H (0.25") LEDs
 Accuracy: ±0.25% of span, ±1 least significant digit
 Supply Voltage: 100 to 240 Vac, nominal, 10 to 15%, 50 to 400 Hz
 Single Phase: 132 to 240 Vdc, nominal, 10 to 20%
 Operating Temperature: -10 to 55°C (14 to 131°F)
 Control Output Ratings:
 Relay: SPDT, 10 A @ 240 Vac
 Resistive: 1/2 hp @ 120 Vac, 1/3 hp @ 240 Vac
 Alarm Relay: SPST, 3 A @ 240 Vac resistive
 Proportional Current (Isolated): 0 to 20 mA DC, scalable into 600 O maximum
 SSR: 2.5 A @ 240 Vac at 25°C (77°F); derates to 1.25 A @ 55°C (130°F)
 DC Pulse (Isolated): 15 Vdc @ 20 mA
 Weight: 369 g (13 oz)
 |  |  |  |  |  |  |  | | † Price are shown in RMB. 
 Note: Comes with complete operator’s manual.
 Ordering Example: (1) CN72130 Single output relay/DC pulse with alarm, ¥8,560.00
 | 
 |  
	|  | 
	
		|  |  |  
		|  |  |  |  
		|  | Part Number Builder |  |  
		|  |  |  |  
		|  | 
		  
		    |  |   
		    | Option Descriptions |   
		    | (1) | Model |   
		    |  | Select 130 for Single output relay/DC pulse with alarm
 150 for Single output 0 to 20 mA with alarm
 033 for Dual output 2 relay/DC pulse
 011 for Dual output 2 AC SSR/DC pulse
 053 for Dual output 0 to 20 mA and relay/DC pulse
 055 for Dual output two 0 to 20 mA
 111 for Dual output 2 AC SSR/DC pulse with alarm
 133 for Dual output 2 relay/DC pulse with alarm
 153 for Dual output two 0 to 20 mA relay/DC pulse with alarm
 155 for Dual output two 0 to 20 mA with alarm
  
		    | (2) | Option |   
		    |  | Select -RSP1 for Remote setpoint 0 to 20 mA
 -RSP2 for Remote setpoint 0 to 10 Vdc
 -PV1 for Retransmission 0 to 20 mA
 -PV2 for Retransmission 0 to 10 Vdc
 -4SP for 4-stage remote setpoint
 |  
		      | NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |  |  |  |  
		|  |  
 |  |  | 
 |  |  | 
	
	
		| Related Links - 