 Temperature Controllers |  | CN350, CN360, & CN370 Series |  |  
  |  |  
|  |  
	
	
|  |  
	| 
	
		|  | 
    	
      	| The CN350, CN360 and CN370 Series controllers are designed for economical and easy use. Models are available with digital, deviation, or non-indicating display, for J, K, R, and S thermocouples or 100 . platinum RTD input. The small 1.88" (48 mm) square face, 1.77" square cutout ( 1 /16 DIN) and short depth behind panel (3.54", 90 mm) help save panel space and installation costs. All models have a digital thumbwheel for adjusting the setpoint. The CN370 Series models provide continuous digital display of the process temperature. The CN360 Series indicate whether the process temperature is within ±1.5% full scale of the setpoint or above or below setpoint. The CN350 Series are non-indicating. These controllers are time proportional with manual reset, and can be converted to ON-OFF control by changing internal jumpers. The proportional band is fixed at 4%.
 Two types of output are available. A 2.5 Amp (SPDT) mechanical relay is for use with systems which can use a 30-second cycle time. With an external solid state relay, loads to 5 Amps can be accommodated. For systems which require a faster cycle time, the dc solid state driver output should be used. This has a cycle time of approximately 3 seconds and can control high ac loads using a dc controlled solid state relay.
 |  |  |  |  |  |  |  | | † Price are shown in RMB. 
 Note: For low voltage 24 Vdc power, add suffix "-24VDC", no additional charge. Low voltage power is not available on dc Pulse models: CN372, CN362 or CN352 series. Each controller is supplied with user’s manual.
 
 | 
 |  
	|  | 
	
		|  |  |  
		|  |  |  |  
		|  | Part Number Builder |  |  
		|  |  |  |  
		|  | 
		  
		    |  |   
		    | Option Descriptions |   
		    | (1) | Display Option |   
		    |  | Select 5 for Non-Indicating
 6 for Deviation Display
 7 for Digital Readout Indication
  
		    | (2) | Output Option |   
		    |  | Select 1 for Mechanical Relay
 2 for DC Pulse Driver
  
		    | (3) | Sensor Type and Temperature Range |   
		    |  | Select JC2 for J Thermocouple 0 to 399 Degrees C
 JF3 for J Thermocouple 0 to 499 Degrees F
 JF4 for J Thermocouple 0 to 799 Degrees F
 KC2 for K Thermocouple 0 to 399 Degrees C
 KC5 for K Thermocouple 0 to 999 Degrees C
 KC6 for K Thermocouple 0 to 1199 Degree C
 KF5 for K Thermocouple 0 to 999 Degrees F
 KF8 for K Thermocouple 0 to 1999 Degree F
 RC7 for R Thermocouple 0 to 1699 Degrees C
 RF9 for R Thermocouple 0 to 2999 Degrees F
 SC7 for S Thermocouple 9 to 1699 Degrees  C
 P1C1 for 100 Ohm Platinum RTD -99 to 99  Degrees C
 P2CX for 100 Ohm Platinum RTD 0 to 99.9 Degrees C
 P1C2 for 100 Ohm Platinum RTD 0 to 399 Degrees C
 P1F2 for 100 Ohm Platinum RTD 0 to 399 Degrees F
 P1F4 for 100 Ohm Platinum RTD 0 to 799 Degrees F
  
		    | (4) | Low Voltage 24 Vdc Power |   
		    |  | Select Nothing(leave field blank) for No Option
 -24VDC for 24 Volt dc Power Option
 |  
		      | NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |  |  |  |  |  |  
		|  |  
 |  |  | 
 |  |  | 
	
	